Open Channel Flow meter – dBMACH3 / dB3 with double sun shields

The dB3 with Double Sun Shields and dBMACH3 transducers have been designed specifically for open channel flow measurement.

Both of them are used with transmitter ULTRA4

Description

  • Dead zone zero (dBMACH3)
  • Accuracy ±1 mm (dBMACH3)
  • Measurement range:0~2.4m (dBMACH3)
  • transmitter:4~20mA×1 output and Volt-free Contacts×3 available from ULTRA4

Specification

Catalog PDF

PHYSICAL: MODEL OPTION SPECIFIC

Model Option

dBMACH3

dB3 with Double Sun Shields

Sensor Body Dimensions

180 mm D (sunshield) x 205 mm H (7.08 in x 8.1 in)

180 mm D (sunshield) x 115 mm H (7.08 in x 4.5 in)

Weight

Nominal 1.1 kg (2.4 lb)

Nominal 1.1 kg (2.4 lb)

Max. and Min. Temperature (Electronics)

Standard: -30 °C to +90 °C (-22 °F to +194 °F)
ATEX: -30 °C to +75 °C (-22 °F to +167 °F)

Standard: -40 °C to +90 °C (-40 °F to +194 °F)
ATEX: -40 °C to +75 °C (-40 °F to +167 °F)

Measurement Range

0 mm to 2.4 m (0 in to 7.9 ft)

125 mm to 3 m (4.9 in to 9.8 ft)

Accuracy

±1 mm (0.039 in)

0.25% or 6 mm (0.2 in) whichever is greater

Resolution

±0.5 mm (0.019 in)

0.01% or 2 mm (0.08 in) whichever is greater

MCERTS Certified

Not Applicable

Class 1 (0.193%) when used with FlowCERT Lite

PHYSICAL: BOTH TRANSDUCERS

Sensor Body Material

Valox 357 U and syntactic foam face

Cable Lengths

Standard = 5 m, 10 m, 20 m or 30 m (16.4 ft, 32.8 ft, 65.6 ft or 98.4 ft). Optional: up to 150 m (492 ft) maximum (increments of 10 m / 32.8 ft only)

Maximum Separation

500 m (1,640 ft)

Mounting Connection

BSP or 1” NPT

ENVIRONMENTAL

Enclosure Protection

IP68 / NEMA 6P

APPROVALS

CE Approval

2014/30/EU - EMC & 2014/34/EU ATEX Directives. Standards applied: EN 60079-0:2012+A11:2013/ EN 60079-11:2012 / EN 60079-18:2009 / EN 60079-26:2007 / EN 61326-1:2013

ATEX Approval

Standard ATEX EEx m II T6 or optional EEx ia IIC T6. FM/FMC approval.

PERFORMANCE

Frequency

125kHz

Beam Angle

<10°